SERVOPRO NanoChrome O2 Background |
|
includes report
software, packaging |
| Impurities
options |
|
| N2
Range 0-250ppb LDL 0.3ppb |
INJ/HC with 2
valves |
| Ar
Range 0-250ppb LDL 0.5ppb |
INJ/HC with 2
valves |
| H2
Range 0-250ppb LDL 0.8ppb |
INJ/HC with 2
valves |
| CO
Range 0-250ppb LDL 0.5ppb |
BF/HC with 2
valves |
| CO2
Range 0-250ppb LDL 0.8ppb |
BF/HC with 2
valves |
| CH4
Range 0-250ppb LDL 0.8ppb |
BF/HC with 2
valves |
| CO2/CH4
Range 0-250ppb LDL 0.8ppb |
BF/HC with 2
valves |
| NMHC
Range 0-250ppb LDL 0.8ppb |
BF with 1 valve |
|
|
| Chassis
options |
|
| Master
Chassis |
Max. 2 channels
with 4 valves |
| PC+
Slave chassis |
2 BF/HC
channels |
| Master
+Slave1 Chassis |
Max. 4 channels
with 8 valves |
| Master
+Slave 1 +Slave 2 Chassis |
Max. 6 channels
with 12 valves |
| Aux.oven |
O2 trap only
for N2 measurement |
|
|
|
|
| Carrier
Gas |
Helium |
|
|
|
|
| Power |
115 VAC, 50-60
Hz |
|
220 VAC, 50-60
Hz |
|
|
| Gas
Connectors (to match accessories fittings) |
1/8" VCR |
|
|
| Serial
port |
RS-232 |
|
|
|
|
| Remote
Support |
VNC |
|
Net Support |
|
|
| Internal
Dilution System |
Not Required(
> 1ppm) |
|
Required( One
per Chassis) |
|
|
|
|
|
|
| 04416A1 |
SERVOPRO
NanoChrome H2 Background |
|
includes report
software, packaging |
| Impurities
options |
|
| N2
Range 0-250ppb LDL 0.3ppb |
INJ/HC with 2
valves |
| Ar
Range 0-250ppb LDL 0.5ppb |
INJ/HC with 2
valves |
| CO
Range 0-250ppb LDL 0.5ppb |
BF/HC with 2
valves |
| CO2
Range 0-250ppb LDL 0.5ppb |
BF/HC with 2
valves |
| CH4
Range 0-250ppb LDL 0.5ppb |
BF/HC with 2
valves |
| CO2/CH4
Range 0-250ppb LDL 0.5ppb |
BF/HC with 2
valves |
| CO2/CH4/NMHC
Range 0-250ppb LDL 0.5ppb |
BF/HC/SEL with
3 valves |
|
|
| Chassis
options |
|
| Master
Chassis |
Max. 2 channels
with 4 valves |
| PC+
Slave chassis |
2 BF/HC
channels |
| Master
+Slave1 Chassis |
Max. 4 channels
with 8 valves |
| Master
+Slave 1 +Slave 2 Chassis |
Max. 6 channels
with valves |
| Aux.oven |
H2 trap only
for N2 measurement |
|
|
|
|
| Carrier
Gas |
Helium |
|
|
|
|
| Power |
115 VAC, 50-60
Hz |
|
220 VAC, 50-60
Hz |
|
|
| Gas
Connectors (to match accessories fittings) |
1/8" VCR |
|
|
| Serial
port |
RS-232 |
|
|
|
|
| Remote
Support |
VNC |
|
Net Support |
|
|
| Internal
Dilution System |
Not Required |
|
Required ( One
per Chassis) |
|
|
|
|
|
|
|
|
| 04402A1 |
Argon Purity
Analyser Base |
|
includes report
software, 2 SS coils tubing, packaging |
|
|
| Trace
(>10 ppm), Pack 1 |
O2 Impurity -
Enter range & LDL |
|
0-10ppm ≤O2
range ≤ 0-100ppm LDL is 1.5% full scale |
|
H2 Impurity -
Enter range & LDL |
|
0-10ppm ≤H2
range ≤ 0-100ppm LDL is 1.5% full scale |
|
N2 Impurity -
Enter range & LDL |
|
0-10ppm ≤N2
range ≤ 0-100ppm LDL is 1.5% full scale |
|
CH4 Impurity -
Enter range & LDL |
|
0-10ppm ≤CH4
range ≤ 0-100ppm LDL is 1.5% full scale |
|
CO Impurity -
Enter range & LDL |
|
0-10ppm ≤CO
range ≤ 0-100ppm LDL is 1.5% full scale |
|
|
|
|
| Trace
(>10 ppm), Pack 2 |
Same as Pack 1
+ |
|
CO2 Impurity -
Enter range & LDL |
|
0-10ppm ≤CO2
range ≤ 0-100ppm LDL is 1.5% full scale |
|
|
| Trace
Exact (<10 ppm), Pack 1 |
O2 Impurity -
Enter range & LDL |
|
0-1ppm ≤O2
range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
| Min
Range 0-1 ppm |
H2 Impurity -
Enter range & LDL |
|
0-1ppm ≤H2
range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
|
N2 Impurity -
Enter range & LDL |
|
0-1ppm ≤N2
range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
|
CH4 Impurity -
Enter range & LDL |
|
0-1ppm ≤CH4
range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
|
|
| Trace
Exact (<10 ppm), Pack 2 |
Same as Pack 1
+ |
| Min
Range 0-1 ppm |
CO Impurity -
Enter range & LDL |
|
0-1ppm ≤CO
range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
|
|
| Trace
Exact (<10 ppm), Pack 3 |
Same as Pack 2
+ |
|
CO2 Impurity -
Enter range & LDL |
| Min
Range 0-1 ppm |
0-1ppm ≤CO2
range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
|
|
| Carrier
Gas |
Argon |
|
|
| Power |
115 VAC, 50-60
Hz |
|
220 VAC, 50-60
Hz |
|
|
| Gas
Connectors (to match accessories fittings) |
1/8"
Swagelok |
|
1/8" VCR
(if 0-1 ppm range) |
|
|
| Serial
port |
Not Required |
|
RS-232 |
|
|
| Remote
Support |
VNC |
|
Net Support |
|
|
| Dual
Inlets (sample + span, with switching) |
Not Required |
|
Required |
|
|
| Calibration
using background gas |
Not required |
|
Required |
|
|
|
|
|
|
| 04403A1 |
Helium Purity
Analyser Base |
|
includes report
software, SS liners, packaging |
|
|
| Trace
(>10 ppm), Pack 1 |
O2 Impurity -
Enter range & LDL |
|
0-10ppm ≤O2
range ≤ 0-100ppm LDL is 1.5% full scale |
|
H2 Impurity -
Enter range & LDL |
|
0-10ppm ≤H2
range ≤ 0-100ppm LDL is 1.5% full scale |
|
N2 Impurity -
Enter range & LDL |
|
0-10ppm ≤N2
range ≤ 0-100ppm LDL is 1.5% full scale |
|
CH4 Impurity -
Enter range & LDL |
|
0-10ppm ≤CH4
range ≤ 0-100ppm LDL is 1.5% full scale |
|
CO Impurity -
Enter range & LDL |
|
0-10ppm ≤CO
range ≤ 0-100ppm LDL is 1.5% full scale |
|
|
| Trace
(>10 ppm), Pack 2 |
Same as Pack 1
+ |
|
Ar Impurity -
Enter range & LDL |
|
0-10ppm ≤Ar
range ≤ 0-100ppm LDL is 1.5% full scale |
|
Ne Impurity -
Enter range & LDL |
|
0-10ppm ≤Ne
range ≤ 0-100ppm LDL is 1.5% full scale |
|
|
| Trace
(>10 ppm), Pack 3 |
Same as Pack 2
+ |
|
CO2 Impurity -
Enter range & LDL |
|
0-10ppm ≤CO2
range ≤ 0-100ppm LDL is 1.5% full scale |
|
|
| Trace
Exact (<10 ppm), Pack 1 |
O2 Impurity -
Enter range & LDL |
|
0-1ppm ≤O2
range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
| Min
Range 0-1 ppm |
H2 Impurity -
Enter range & LDL |
|
0-1ppm ≤H2
range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
|
N2 Impurity -
Enter range & LDL |
|
0-1ppm ≤N2
range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
|
CH4 Impurity -
Enter range & LDL |
|
0-1ppm ≤CH4
range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
|
|
| Trace
Exact (<10 ppm), Pack 2 |
Same as Pack 1
+ |
|
CO Impurity -
Enter range & LDL |
| Min
Range 0-1 ppm |
0-1ppm ≤CO
range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
|
|
| Trace
Exact (<10 ppm), Pack 3 |
Same as Pack 2
+ |
| Min
Range 0-1 ppm |
Ar Impurity -
Enter range & LDL |
|
0-1ppm ≤Ar
range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
|
Ne Impurity -
Enter range & LDL |
|
0-1ppm ≤Ne
range < 0-10ppm LDL is 1.5% full scale,Min.150ppb |
|
|
| Trace
Exact (<10 ppm), Pack 4 |
Same as Pack 3
+ |
|
CO2 Impurity -
Enter range & LDL |
| Min
Range 0-1 ppm |
0-1ppm ≤CO2
range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
|
|
| Carrier
Gas |
Helium |
|
|
| Power |
115 VAC, 50-60
Hz |
|
220 VAC, 50-60
Hz |
|
|
|
|
| Gas
Connectors (to match accessories fittings) |
1/8"
Swagelok |
|
1/8" VCR
(if 0-1 ppm range) |
|
|
| Serial
port |
Not Required |
|
RS-232 |
|
|
| Remote
Support |
VNC |
|
Net Support |
|
|
| Dual
Inlets (sample + span, with switching) |
Not Required |
|
Required |
|
|
| Calibration
using background gas |
Not required |
|
Required |