| http://thietbitudong.ansvietnam.com/ |
|
| 04416A1 |
SERVOPRO NanoChrome Ar Background |
|
includes report
software, packaging |
| Impurities
options |
|
| N2
Range 0-250ppb LDL 0.3ppb |
INJ with 1
valve |
| H2
Range 0-250ppb LDL 0.5ppb |
INJ/HC with 2
valves |
| CO
Range 0-250ppb LDL 0.5ppb |
BF/HC with 2
valves |
| CO2
Range 0-250ppb LDL 0.5ppb |
BF/HC with 2
valves |
| CH4
Range 0-250ppb LDL 0.5ppb |
BF/HC with 2
valves |
| CO2/CH4
Range 0-250ppb LDL 0.5ppb |
BF/HC with 2
valves |
| CO2/CH4/NMHC
Range 0-250ppb LDL 0.5ppb |
BF/HC/SEL with
3 valves |
|
|
| Chassis
options (Refer to SAP) |
|
| Master
Chassis |
Max. 2 channels
with 4 valves |
| PC+
Slave chassis |
2 BF/HC
channels |
| Master
+Slave1 Chassis |
Max. 4 channels
with 8 valves |
|
|
| Carrier
Gas |
Helium |
|
Argon only for
N2 measurement |
|
|
| Power |
115 VAC, 50-60
Hz |
|
220 VAC, 50-60
Hz |
|
|
| Gas
Connectors (to match accessories fittings) |
1/8" VCR |
|
|
| Serial
port |
RS-232 |
|
|
|
|
| Remote
Support |
VNC |
|
Net Support |
|
|
| Internal
Dilution System |
Not Required(
> 1ppm) |
|
Required ( One
per Chassis) |
|
|
|
|
|
|
| 04416A1 |
SERVOPRO
NanoChrome N2 Background |
|
includes report
software, packaging |
| Impurities
options |
|
| Ar
Range 0-250ppb LDL 0.5ppb |
INJ/HC with 2
valves |
| H2
Range 0-250ppb LDL 0.5ppb |
INJ/HC with 2
valves |
| CO
Range 0-250ppb LDL 0.5ppb |
BF/HC with 2
valves |
| CO2
Range 0-250ppb LDL 0.5ppb |
BF/HC with 2
valves |
| CH4
Range 0-250ppb LDL 0.5ppb |
BF/HC with 2
valves |
| CO2/CH4
Range 0-250ppb LDL 0.5ppb |
BF/HC with 2
valves |
| CO2/CH4/NMHC
Range 0-250ppb LDL 0.5ppb |
BF/HC/SEL with
3 valves |
|
|
| Chassis
options |
|
| Master
Chassis |
Max. 2 channels
with 4 valves |
| PC+
Slave chassis |
2 BF/HC
channels |
| Master
+Slave1 Chassis |
Max. 4 channels
with 8 valves |
| Master
+Slave 1 +Slave 2 Chassis |
Max. 6 channels
with 12 valves |
|
|
| Carrier
Gas |
Helium |
|
|
|
|
| Power |
115 VAC, 50-60
Hz |
|
220 VAC, 50-60
Hz |
|
|
| Gas
Connectors (to match accessories fittings) |
1/8" VCR |
|
|
| Serial
port |
RS-232 |
|
|
|
|
| Remote
Support |
VNC |
|
Net Support |
|
|
| Internal
Dilution System |
Not Required(
> 1ppm) |
|
Required ( One
per Chassis) |
|
|
|
|
|
|
|
|
| SERVOPRO
Plasma Gas Analyser (K2001) |
|
|
|
| 02001A1 |
Trace Gas
Analyser |
|
|
|
includes
4-20ma, digital dry contacts (range ID), manual/CDROM, packaging) |
|
|
| Power |
115 VAC, 50-60
Hz |
|
220 VAC, 50-60
Hz |
|
|
|
|
| Background |
Argon |
|
Helium |
|
Argon and
Helium |
|
|
|
|
| Auto
calibration |
Not required |
|
Required |
|
|
|
|
| 3
Range ID |
0-1, 0-10,
0-100 (ppm) |
|
0-10, 0-50,
0-100 (ppm) |
|
|
|
|
| Serial
port |
Not Required |
|
RS-232 |
|
|
|
|
|
|
|
|
|
|
| SERVOPRO
Chroma Gas Analyser (K4000) |
|
|
|
|
|
| 04401A1 |
Crude Ar
Analyser (N2 in mix 10%Ar + 90%O2) Base |
|
includes report
software, 2 SS coils tubing, packaging |
|
|
| Trace
(>10 ppm), Pack 1 |
N2 Impurity -
Enter range & LDL |
|
0-10ppm ≤N2
range ≤ 0-500ppm LDL is 1.5% full scale |
| Carrier
Gas |
Argon |
|
|
| Power |
115 VAC, 50-60
Hz |
|
220 VAC, 50-60
Hz |
|
|
| Gas
Connectors |
1/8"
Swagelok |
| (to
match accessories fittings) |
|
|
|
| Serial
port |
Not Required |
|
RS-232 |
|
|
| Remote
Support |
VNC |
|
Net Support |
|
|
| Dual
Inlets (sample + span, with switching) |
Not Required |
|
Required |
|
|
| Calibration
using background gas |
Not required |
|
Required |
Nhận xét