Servomex Ans Vietnam 2

http://thietbitudong.ansvietnam.com/
04416A1 SERVOPRO NanoChrome Ar Background
includes report software, packaging
Impurities options
N2  Range 0-250ppb LDL 0.3ppb INJ with 1 valve
H2  Range 0-250ppb LDL 0.5ppb INJ/HC with 2 valves
CO  Range 0-250ppb LDL 0.5ppb BF/HC with 2 valves
CO2 Range 0-250ppb LDL 0.5ppb BF/HC with 2 valves
CH4 Range 0-250ppb LDL 0.5ppb BF/HC with 2 valves
CO2/CH4 Range 0-250ppb LDL 0.5ppb BF/HC with 2 valves
CO2/CH4/NMHC Range 0-250ppb LDL 0.5ppb BF/HC/SEL with 3 valves
Chassis options (Refer to SAP)
Master Chassis Max. 2 channels with 4 valves
PC+ Slave chassis 2 BF/HC channels
Master +Slave1 Chassis Max. 4 channels with 8 valves
Carrier Gas Helium
Argon only for N2 measurement
Power 115 VAC, 50-60 Hz
220 VAC, 50-60 Hz
Gas Connectors (to match accessories fittings) 1/8" VCR
Serial port RS-232
Remote Support VNC
Net Support
Internal Dilution System Not Required( > 1ppm)
Required ( One per Chassis)
04416A1 SERVOPRO NanoChrome N2 Background
includes report software, packaging
Impurities options
Ar Range 0-250ppb LDL 0.5ppb INJ/HC with 2 valves
H2 Range 0-250ppb LDL 0.5ppb INJ/HC with 2 valves
CO Range 0-250ppb LDL 0.5ppb BF/HC with 2 valves
CO2 Range 0-250ppb LDL 0.5ppb BF/HC with 2 valves
CH4 Range 0-250ppb LDL 0.5ppb BF/HC with 2 valves
CO2/CH4 Range 0-250ppb LDL 0.5ppb BF/HC with 2 valves
CO2/CH4/NMHC Range 0-250ppb LDL 0.5ppb BF/HC/SEL with 3 valves
Chassis options
Master Chassis Max. 2 channels with 4 valves
PC+ Slave chassis 2 BF/HC channels
Master +Slave1 Chassis Max. 4 channels with 8 valves
Master +Slave 1 +Slave 2 Chassis Max. 6 channels with 12 valves
Carrier Gas Helium
Power 115 VAC, 50-60 Hz
220 VAC, 50-60 Hz
Gas Connectors (to match accessories fittings) 1/8" VCR
Serial port RS-232
Remote Support VNC
Net Support
Internal Dilution System Not Required( > 1ppm)
Required ( One per Chassis)
SERVOPRO Plasma Gas Analyser (K2001)
02001A1 Trace Gas Analyser
includes 4-20ma, digital dry contacts (range ID), manual/CDROM, packaging)
Power 115 VAC, 50-60 Hz
220 VAC, 50-60 Hz
Background Argon
Helium
Argon and Helium
Auto calibration Not required
Required
3 Range ID 0-1, 0-10, 0-100 (ppm)
0-10, 0-50, 0-100 (ppm)
Serial port Not Required
RS-232
SERVOPRO Chroma Gas Analyser (K4000)
04401A1 Crude Ar Analyser (N2 in mix 10%Ar + 90%O2) Base
includes report software, 2 SS coils tubing, packaging
Trace (>10 ppm), Pack 1 N2 Impurity - Enter range & LDL
0-10ppm ≤N2 range ≤ 0-500ppm  LDL is 1.5% full scale
Carrier Gas Argon
Power 115 VAC, 50-60 Hz
220 VAC, 50-60 Hz
Gas Connectors 1/8" Swagelok
(to match accessories fittings)
Serial port Not Required
RS-232
Remote Support VNC
Net Support
Dual Inlets (sample + span, with switching) Not Required
Required
Calibration using background gas Not required
Required