Servomex Ans Vietnam

04407A1 Hydrogen Purity Analyser Base
includes report software, SS liners, packaging
Trace (>10 ppm), Pack 1 N2 Impurity - Enter range & LDL
0-10ppm ≤N2 range ≤ 0-200ppm  LDL is 1.5% full scale
(with O2 trap in aux oven)
Trace (>10 ppm), Pack 2 Same as Pack 1 +
CO2 Impurity - Enter range & LDL
0-10ppm ≤CO2 range ≤ 0-200ppm  LDL is 1.5% full scale
CH4 Impurity - Enter range & LDL
0-10ppm ≤CH4 range ≤ 0-200ppm  LDL is 1.5% full scale
Trace (>10 ppm), Pack 3 CO Impurity - Enter range & LDL
0-10ppm ≤CO range ≤ 0-200ppm  LDL is 1.5% full scale
CO2 Impurity - Enter range & LDL
0-10ppm ≤CO2 range ≤ 0-200ppm  LDL is 1.5% full scale
CH4 Impurity - Enter range & LDL
0-10ppm ≤CH4 range ≤ 0-200ppm  LDL is 1.5% full scale
Trace (>10 ppm), Pack 4 Same as Pack 2 +
CO Impurity - Enter range & LDL
0-10ppm ≤CO range ≤ 0-200ppm  LDL is 1.5% full scale
Trace (>10 ppm), Pack 5 Same as Pack 4 +
Ar Impurity - Enter range & LDL
0-10ppm ≤Ar range ≤ 0-200ppm  LDL is 1.5% full scale
Trace Exact (<10 ppm), Pack 1 N2 Impurity - Enter range & LDL (with O2 trap in aux oven)
0-1ppm ≤N2 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
Min Range 0-1 ppm CO2 Impurity - Enter range & LDL
0-1ppm ≤CO2 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
CH4 Impurity - Enter range & LDL
0-1ppm ≤CH4 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
Trace Exact (<10 ppm), Pack 2 CO Impurity - Enter range & LDL
0-1ppm ≤CO range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
Min Range 0-1 ppm CO2 Impurity - Enter range & LDL
0-1ppm ≤CO2 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
CH4 Impurity - Enter range & LDL
0-1ppm ≤CH4 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
Trace Exact (<10 ppm), Pack 2 Same as Pack 1 +
CO Impurity - Enter range & LDL
Min Range 0-1 ppm 0-1ppm ≤CO range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
Carrier Gas Argon
Helium (if Argon impurity)
Power 115 VAC, 50-60 Hz
220 VAC, 50-60 Hz
Gas Connectors (to match accessories fittings) 1/8" Swagelok
1/8" VCR (if 0-1 ppm range)
Serial port Not Required
RS-232
Remote Support VNC
Net Support
Dual Inlets (sample + span, with switching) Not Required
Required
Calibration using background gas Not required
Required
04408A1 Carbon Dioxide Purity Analyser Base
includes report software, SS liners, packaging
Trace (>10 ppm), Pack 1 O2 Impurity - Enter range & LDL
0-10ppm ≤O2 range ≤ 0-100ppm  LDL is 1.5% full scale
H2 Impurity - Enter range & LDL
0-10ppm ≤H2 range ≤ 0-100ppm  LDL is 1.5% full scale
N2 Impurity - Enter range & LDL
0-10ppm ≤N2 range ≤ 0-100ppm  LDL is 1.5% full scale
CH4 Impurity - Enter range & LDL
0-10ppm ≤CH4 range ≤ 0-100ppm  LDL is 1.5% full scale
Trace (>10 ppm), Pack 2 Same as Pack 1 +
CO Impurity - Enter range & LDL
0-10ppm ≤CO range ≤ 0-100ppm  LDL is 1.5% full scale
Trace (>10 ppm), Pack 3 Same as Pack 2 +
Ar Impurity - Enter range & LDL
0-10ppm ≤Ar range ≤ 0-100ppm  LDL is 1.5% full scale
Carrier Gas Argon
Helium (if Argon impurity)
Power 115 VAC, 50-60 Hz
220 VAC, 50-60 Hz
Gas Connectors (to match accessories fittings) 1/8" Swagelok
1/8" VCR (if 0-1 ppm range)
Serial port Not Required
RS-232
Remote Support VNC
Net Support
Dual Inlets (sample + span, with switching) Not Required
Required
Calibration using background gas Not required
Required
SERVOFLEX 5200 MULTI PURPOSE ANALYSER
05230A1 5200 Multi Purpose
SUPPLY POWER UK Mains
European Mains
US Mains
Japanese Mains (no plug fitted)
Rechargeable Lithium ion battery (UK)
Rechargeable Lithium ion battery (US)
Rechargeable Lithium ion battery (Euro)
Rechargeable Lithium ion battery (Japan)
MEASUREMENT 1 Oxygen, standard accuracy (1116)
Oxygen, industrial version (3601, 1 dec place)
Oxygen, high accuracy (3601, 2 dec place)
0-10% Carbon Dioxide
0-25% Carbon Dioxide
0-50% Carbon Dioxide
0-100% Carbon Dioxide
MEASUREMENT 2 0-10% Carbon Dioxide
0-25% Carbon Dioxide
0-50% Carbon Dioxide
0-100% Carbon Dioxide
SAMPLING Automatic Flow Control Device
Internal Pump
mA OUTPUTS mA outputs, one transducer fitted
mA outputs, two transducers fitted
CONNECTORS Quickconnect 1/4" barb fitting
Barb as above plus adaptor to 1/8" NPT
EXHAUST / VENT OUTLETQ Rear Panel
Front Panel
VEHICLE ADAPTOR 12/24V Vehicle Power Adaptor
PRINTER* Thermal Printer Kit (Universal)
SIDE PANEL ACCESSORIES Sample Conditioning Panel (not for O2 std transducer)
Choose only one Flow Meter + Valve (not for AFCD version)
Flow Meter (analyser with AFCD)
PROBE HOLDER Supplied (for SCP only)
Supplied including Filter (not for SCP)
SAMPLE PROBE Not Supplied
25cm, SS, Tip, <180C
1m SS
TRANSPORT CASE None
Protective plastic transport case, std pre-cut foam
USER MANUAL English
French
German
Italian
ACCESSORIES
202517 Additional barbed Quickconnect fitting
(1 supplied as standard. Some users may wish
to purchase additional fittings for zero and span
gas to speed connections during calibration)
5200991 Additional Quickconnect adaptor to 1/8" NPT
203022 Additional rolls of printer paper (pack of 5)
570982 Replacement filters (pack of 5)
NOTE: 3 filters supplied with analyser
2323-7029 Replacement Viton O-ring for AFCD
5200992 Carry Case with foam inserts
Note: If printer ordered as loose item after initial purchase price is higher
209961 Thermal Printer Kit (Universal)***
*This price only when purchased with analyser. Includes 1 roll of paper.
***The instrument will only print properly to the printer supplied by Servomex.
SERVOFLEX 5200 FOOD PACK ANALYSER

Nhận xét